Condensation Risk in a Wood-Frame Wall

Application ID: 43871


This 2D stationary model computes heat and moisture transport in a wall composed of different hygroscopic materials. A comparison with the Glaser method is given for the temperature and relative humidity solutions. The effect of the use of a vapor barrier is also investigated.

This model example illustrates applications of this type that would nominally be built using the following products: